Cathode Ray Oscilloscope(CRO): Definition, Working, Diagram & Applications

Last Updated on May 19, 2025
Download As PDF
IMPORTANT LINKS
Electrical & Electronic Instruments
Photo Conductivity Insulation Material Energy Meter Creeping in Energy Meter Moving Iron Instrument Ammeter and Voltmeter (Moving Iron Type) PMMC Potentiometric Recorder Basic Principle of Sensors Data Acquisition System Meter Bridge And Potentiometer A.C.Bridges Frequency Meters Maxwell’S Bridge Hay’S Bridge Kelvin’S Double Bridge Schering Bridge Energy Meter AC Bridges Hall Effect Transducer Strain Gauge Transducer Thermistors Thermocouples Linear Variable Differential Transformer (Lvdt) Capacitive Transducers Piezoelectric Transducer Tachometer Pyrometer Current Transformer Potential Transformer Megger Cathode Ray Oscilloscope Wattmeters "Measurement Of Power (1 Phase & 3 Phase 2 Wattmeter Method of 3 Phase Power Measurement Measurement of Frequency & Phase Angle Dynamometer Extension of Range Wattmeter
Analog Electronics Control Systems Digital Electronics Electrical Estimation & Costing Electrical Machine Material Science Network Theory Power Electronics Power System Analysis Signals & Systems Utilization of Electrical Energy
Crack SSC JE (Mechanical) Guaranteed Selection Program 2025 Exam with India's Super Teachers

Get 12 Months SuperCoaching @ just

₹16999 ₹6999

Your Total Savings ₹10000
Purchase Now
Test Series
247.8k Students
Current Affairs (CA) 2025 Mega Pack for SSC/Railways/State Exam Mock Test
431 TOTAL TESTS | 4 Free Tests
  • 168 Topic Specific
  • 52 Weekly Revision
  • 24 Monthly Digest
  • 12 Need-to-Know NEWS
  • 96 State Specific
  • 10 Previous Year Questions
  • 17 Revision 2024
  • 52 Advanced Current Affairs

Get Started

Block Diagram of Cathode Ray Oscilloscope

(CRO) Cathode Ray Oscilloscope FAQ

CRO full form is Cathode Ray Oscilloscope, is a very fast X-Y plotter that can display an input signal versus time or another signal.An electrical test device called a cathode ray oscilloscope is used to produce waveforms in response to several input signals. It was originally known as an oscillograph.

The heater of the electron gun generates the electron beam using low voltage. The cathode ray tube needs a high voltage to accelerate the beam. Other oscilloscope control units require the standard voltage supply. In between electron gun and the screen are placed between the horizontal and vertical plates, allowing it to detect the beam in accordance with the input signal, and display it on the screen.

The CRO oscilloscope's time base generator produces the blanking voltage. This additional focusing control in CRO is comparable to astigmatism in optical lenses. Due to the different lengths of the electron pathways at the center and the corners of the screen, a beam that is focused in the monitor's middle would be defocused here

General controls, time base controls, Horizontal and vertical controls, trigger controls

Phosphor crystals are used to cover the inside face of the faceplate and convert electrical energy into light. This phenomenon is known as fluorescence it occurs when an electronic ray strikes the phosphor crystal. 

Report An Error